Call / WhatsApp

+91-9680966000

duns-registered-logo

UL-listed Fire Damper

Motorized (electric, pneumatic, or manual operation), leakage Class I, high temperature, high pressure, UL-listed fire damper, also for explosion-proof hazardous areas.

Dampers 

It is a high-performance, low-leakage, robust, high-temperature UL-listed fire-damper. It is used in air-transfer- openings, in wall openings, in ducts, and in other places. where fire-rated structures (e.g., walls, floors, or other fire barriers) are penetrated. The idea of compartmentalization is to keep the fire at its starting point and prevent it from spreading to other locations.

A fire damper can be operated using a manual shaft or an electric or pneumatic motor actuator. These are available for explosion-proof installation in Zone 1, Zone 2, and Zone 22.

Key Features of a UL-listed Fire Damper:

  • Available Sizes: 150 × 150 mm to 2400 × 2400 mm
  • Mounting: duct mount, wall mount.
  • Pressure: Up to 200 mm WC
  • Velocity: Up to 4,800 FPM
  • Blade Type: 3V, Airfoil
  • Shaft/Damper Movement: Manual, motorized
  • Actuator type: UL listed 24V DC/AC, 230V AC powered, 4 Nm to 24 Nm torque.
  • Actuator Option: Electric or Pneumatic
  • Option: Explosion-proof or flameproof ATEX/UL certified for Zone 1, 2, and 22 hazardous areas
  • Leakage Class: Class I, Class III
  • Temperature Rating: 300 deg Cel, 400 deg Cel for 90 minutes, 120 minutes, 180 minutes.
  • Fire Resistance Rating: 1½ to 3 hours
  • Material: galvanized steel, stainless steel, aluminum
  • Heavy-Duty Interlocking Blades
  • Robust and fully welded construction.
  • Heavy-Duty Interlocking Blades.
  • Fully enclosed blade linkage mechanism.

Suggested Applications:

  • Buildings: apartments, hospitals, offices, hotels, mixed-use buildings.
  • Underground Spaces: Car parks, garages, strategic bunkers.
  • Transport Facilities: Metro stations, railway stations, transport warehouses.
  • Commercial centers: shopping centers, hotels, airports.
  • Industrial Facilities: Manufacturing Units, Warehouses, and Industrial Processing.

Standards and Compliance Available:

  • UL 555 and UL 555S
  • AMCA Air Performance
  • CBRI-Certified (Central Building Research Institute), India
  • Applus+
  • California State Fire Marshal
  • National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101, and 105
  • IBC International Building Codes
  • New York City (MEA listing #260-91-M)
  • CSFM, California State Fire Marshal
  • Fire Damper Listing (#3225-0981:103)
  • Leakage (Smoke) Damper Listing (#3230-0981:104)

Options and Accessories:

  • Manual Reset Switch
  • Open/Close Indicator Switch
  • Access Door
  • Smoke Sensor
  • Roll-mate flange (available on request)
  • SS-Linkages and Jack-Shaft
  • Actuators with a power input of 230 V
  • Control Panel